Model Number: OC-F08-SF6 gas
Brand Name: Oceanus
Key Specifications/Special Features:
Description:OC-F08 series online gas detector used the original imported sensor and the ultra low power 32-bit microprocessor, so with the advantages of high precision, good repeatability, stable signal, respond quickly and more. Possible connected with many controller system, such as PLC, DCS, computer and other, with the function of remote monitor and alarm, data logger and analysis.Common applications is gas safety inspection and alarm for industrial scene, such as petroleum refinery, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire, environmental protection and more.Features:4-20mA standard analog signal and RS485 digital signal output, 200-1000Hz signal output, relay output, data restore, data logger(optional)LED screen displaying the gas concentration, gas type, unit, instrument status and moreIndependent air chamber, the sensor is not required to replace the sensor calibration, automatic identification of key parameters of the sensor
Protection function to prevent high gas concentration attack
Display the gas concentration in %LEL
Infrared remote controller operation
With the 16-bit ADC acquisition chip, designed withfour-layer circuit board, so with high anti-interference ability
With the Ex-proof certificate, the Ex-proof grade is Exd II CT6
Protection function to prevent high gas concentration attack
Display the gas concentration in %LEL
Infrared remote controller operation
With the 16-bit ADC acquisition chip, designed withfour-layer circuit board, so with high anti-interference ability
With the Ex-proof certificate, the Ex-proof grade is Exd II CT6
ApplicableGas | Sulfur hexafluoride(SF6) |
Detecting Range | 0-1000ppm or customized |
Resolution | 0.01ppm、0.1ppm、1ppm 0.01 mg/m3、0.1 mg/m3、1 mg/m3 |
Sampling | Diffusion or pump-suction, circulation selectable |
Accuracy | ≤±3%F.S |
Repeatability | ≤±1% |
Zero drift | ≤±1%(F.S/year) |
Sensor Type | Electrochemical |
Sensor Life | 2~3 years |
Response Time (T90) | ≤20s |
Alarming mode | Audible-visual alarm(Optional) |
Operating Environment | Temperature: -30℃~60℃(Customized for special demands) Humidity: ≤95%RH (non-condensing); if >90%RH, can add the filter Pressure: 86kPa~106kPa |
Working Voltage | 24V DC(16~30VDC) |
Output Signals | (Standard)Three-wire system 4~20mA standard signals output, available for PLC, DCS, etc; (Optional) Four-wire system RS485 digital signal output; (Optional) Frequency signal 200~1000Hz output; Two-level passive contact output:220VAC 0.5A, 5VDC 0.5A |
Installation Means | Wall mounted, Pipe type(Thread:M40*1.5 ) |
Material of Body | Anti-corrosionmaterial |
Explosion-proof Index | Ex d IIC T6 |
Protection Grade | IP66 |
Electrical Interface | 3/4″NPT(Female Screw)、1/2″NPT(Female Screw) |
Transmit Distance | ≤2000m |
Dimension | 210 mm×140 mm×92 mm(L×W×H) |
Weight | About 1.6Kg |
Standards | GB15322.1-2003,GB3836.1-2010,GB3836.2-2010,GB3836.4-2010 |
Shipping Information:
- FOB Port: Shenzhen
- Lead Time: 3 - 5 days
- HTS Code: 9026.80.90 00
Main Export Markets:
- Asia
- Central/South America